Senseca Germany GmbH

PRO 915 - Combination thermo-manometer, integrated pressure sensor, graphic display

Producer

INTRODUCTION
PRO 915-2 is a differential pressure and temperature high class professional handheld data logger with a rich set of features, high grade robustness and operating comfort for safe and reliable use.

FEATURES
Display
The multilingual large dot matrix/clear text LCD has ergonomic wide-angle visibility from daylight to darkness, thanks to the backlight.
It displays either large scale values, statistical data or the chart of a variable measurement history.
The HOLD feature allows freezing the measurements on display, while the REL feature allows showing the measurement against the measured value.
Many units of measurement available for each measured parameter: pressure, air speed, air flow rate and temperature.
Data Logging
Large storage capacity: up to 1 million data, file system based.
The logged data are store in CVS files that can be easily viewed connecting the instrument to a PC via USB: the instrument is seen by the PC as a mass storage device, the data can be read oud and evaluated without software necessarily needed.
Automatic log with configurable interval.
The instruments integrate a Real Time Clock: date and time of each logged sample are stored.
Alarm
Configurable alarm thresholds and optionally hysteresis can be set.
LCD indication and buzzer activation when thresholds are exceeded.

CONFIGURATION & MEASUREMENT
Pressure measurement
The meter has an internal ±20 hPa digital differential pressure sensor.
Zero and slope user corrections allows compensating any possible sensor drift with time, for the best measuring accuracy.
Air speed and flow measurement
In combination with a Pitot tube, it can calculate the air speed.
The tube constant is configurable. If air speed measurement in a duct is performed, setting the duct section in the data logger, the air flow rate is also available.
Temperature measurement
The miniature flat-pin input for connecting K-type thermocouple probes allows the instrument to detect the temperature as well.
This feature also allows taking advantage of Pitot tubes with integrated K thermocouple sensor.
Connection to PC
Via the USB C port, for viewing or downloading the files stored in the instrument internal memory or connecting to the application software ProXware.
Statistics
Detection of MIN, AVG (average) and MAX.
The user can clear the statistical info to start a new statistical calculation.

Storage capacity:
Up to 1 million data sets, file system based
Each data set includes date/timestamp and measurement.
Data are stored in CSV files.
Logging type:
Automatic with manual start/stop
Accuracy:
Pressure:
±0.1% FSS (*) ± 1 digit typ. @ 25 °C
±1% FSS ± 1 digit max.

Temperature:
±(0.2 °C +0.2% of measured value) ± 1 digit
Cold junction accuracy (TC input):
±0.3 °C
Measurement rate:
4 meas/s
Overpressure limit:
±100 hPa
Temperature drift (ref. 25 °C):
±1 %FSS/year max. (FSS = 2 x full scale pressure)
Long-term drift:
Pressure: ±1 %FSS/year max.
Temperature: ±0.1 °C/year
Compatible media:
Air and non-aggressive dry gases
Logging interval:
1, 2, 5, 10, 15, 30 s / 1, 2, 5, 10, 15, 30 min / 1 hour
Clock:
User-adjustable date and RTC function (max. drift 1 min/month @ 25 °C)
User interface:
Multilingual (de, en, it, fr, es)
PC connection:
USB C (cable included), Mass Storage Device
Power supply:
4 x AA battery (included in the scope of delivery)
External 5 V DC via USB C (power adapter or PC USB port)
Power consumption:
20 mA typ.
Weight:
350 g incl. battery
Battery autonomy:
> 150 h typ. continuous operation
Auto power off:
Yes, user configurable
Automatically disabled if external power is connected
Housing material:
Shock and impact proof, ABS, TPE (side protection), Polyster (front panel),
Measuring range:
Pressure:
±20 hPa

Temperature:
K:-200…+1370 °C
J:-100…+750 °C
T:-200…+400 °C
N:-200…+1300 °C
R:+200…+1480 °C
S:+200…+1480 °C
B:+200…+1800 °C
E:-200…+750 °C
Operating conditions:
-5 ... +50 °C; 0 ... 85 % RH (non-condensing)
Storage temperature:
-25…65 °C (without batteries)
Display:
140 x 160 dot-matrix LCD with backlight / visible area 42 x 50 mm, display of large-digit single values, statistical info (min/avg/max), chart view
Dimensions:
170 x 78 x 38 mm
Standard functions:
Acostic/optic alarm, automatic switch-off freely configurable by the user (automatically deactivated if external power supply is connected)
Battery life:
> 150 h typ. Continuous operation
Current consumption:
20 mA typ
Data logger with read out via USB:
yes
Extras:
Foldable stand and magnet for flexible operation
Optional special functions:
Favorites menu, multilingual
Resolution:
Pressure: 0.1 hPa
Temperature: 0.1 °C
Channels:
Pressure:
1 differential
2 x universal barbed pressure ports (+/-) for 4 and 6 mm inner diameter hose
Interchangeable G 1/8 thread connections

Temperature:1
Miniature female flat-pin TC connector
Accuracy typ. pressure:
±0.15 %FSS) ± 1 digit typ. @ 25 °C ±1.5 %FSS ± 1 digit max.
(FSS = 2 x full scale pressure)
Accuracy typ. temperature:
±(0.2 °C+0.2% of measured value) ±1 digit + cold junction
Display units air flow rate:
m³/h
Display units air speed:
m/s, km/h, mph, knot
Display units pressure:
Pa, kPa, bar, mbar, inHg, inH2O, mmH2O
Display units temperature:
°C, °F, K
Long-term drift pressure:
±1 %FSS/year max. (FSS = 2 x full scale pressure)
Long-term drift temperature:
±0.1 °C/year
Measuring pressure:
2 x universal barbed pressure ports (+/-) for 4 and 6 mm inner Ø hose Interchangeable G 1/8 thread connections
Measuring range pressure:
±20.0 hPa
Measuring range temperature:
TC type K: -220…+1372 °C
Measuring temperature:
1 Miniature TC connector (flat plug)
Resolution pressure:
0,1 hPa
Resolution temperature:
0.1 °C
 
 
Enquire for more information
please weait… Your data is being loaded...

Article no. Version Resolution Connections Display Current supply Alarm function Brand Scope of delivery Measuring ranges Measuring input Output Data logger minimal quantity Quantity
PCE
486133 PRO915-2 With data logger 1 Pa (0.01 mbar) 2x universal pressure port for tube 6x1 mm (4 mm inner-Ø) or 8x1 mm (6 mm inner-Ø) Graphic display with backlight 4 batteries (Mignon AA/LR6) or via USB socket sound & light SENSECA Device in carton box, incl batteries, 2 hoses, testprotocol, Quickstart -220 ... +1768 °C (depends on the used thermocouple) Differential pressure, air and non-aggressive dry gases USB jack type C Up to 1 million data sets, file system based 1 Delivery time