DX 310/311 is a digital combined temperature and relative humidity probe for the PRO D01 / PRO D05 handheld meters.
The probe supplies the following calculated quantities:

  • Dew point
  • Wet bulb temperature
  • Absolute and specific humidity
  • Mixing ratio
  • Specific enthalpy
  • Partial vapor pressure
  • Frost point temperature
  • Saturation vapor pressure above water and above ice
The probe is supplied factory-calibrated in multiple points for relative humidity, and it is ready to use.
The probe can be optionally supplied with a DAkkS/ACCREDIA calibration certificate.
The calibration data are stored in the probe, allowing for interchangeability without the need for recalibration.
Equipped with 4-pin M12 connector and 2, 5 or 10 m cable (only DX311).

Output:
UART (TTL 3.3V): DX-Sensor-Interface
Power supply:
3.3…6 Vdc
Power consumption:
<1 mA typ.
Connection:
4-pole M12 via cable
Dimensions:
Stem: Ø14 x 132 mm Handle length 98 mm Cable length: 2, 5 or 10 m
Weight:
100 g approx. with 2 m cable
Sensor:
RH: Capacitive
Temperature: Pt100
Measuring range:
RH: 0 ... 100 %
Temperature: -50 ... +160 °C
Resolution:
RH: 0.01 %
Temperature: 0.01 °C
Accuracy:
RH: ± 1.2% (0…85%) / ±2% (85…100%) @ T=0…50 °C (1.5 + 1.5% of the measured value)% @ T=remaining range
Temperature: ± 0.1 °C ± 0.1% of the measured value
Operating conditions:
-50…+160 °C / 0…100 %RH
Materials:
Stem and protector cap: PBT Handle: Polyamide (PA6-GF30) Cable: PVC
Long-term drift:
RH: ± 0.5 %RH/year
Temperature: ± 0.03 °C/year
RH response time:
10 s (10 → 80 %RH; air speed=2 m/s @ constant temperature)
Calculated quantities:
Dew point Wet bulb temperature Absolute humidity Specific humidity Mixing ratio Specific enthalpy Partial vapor pressure Frost point temperature Saturation vapor pressure above water Saturation vapor pressure above ice
Accuracy RH:
±1.2% (0…85%) / 2% (85…100%) @ T=0…50 °C (1.5 + 1.5% of the measured value) % @ T=remaining range
Adjustment support:
Multipoint RH
Long-term drift RH:
±0.5 %RH/year
Measuring range RH:
0…100%
Resolution RH:
0.01%
Sensor RH:
Capacitive, temperature compensated
Temperature:
Pt100
 
 
Enquire for more information
please weait… Your data is being loaded...

Article no. Connection Brand Version Calibration Working temperature Measuring range air humidity Measuring range temperature Accuracy for humidity Accuracy temperature Cable Scope of delivery minimal quantity Quantity
PCE
486774 DX311-L01-00 fix connected M12 connection cable, handle SENSECA Interchangeable without loss of accuracy Factory adjustment with test protocol -25 ... +60 °C 0 ... 100 % -40 ... +120 °C ±2.5 % r.h. ±0,5 °C 1 m PVC cable, fixed Device in carton box, incl. Quickstart 1 Delivery time
486793 DX310-00 M12 connetor,for M12 connection cable or direct mounting, cylindrical sensor tube SENSECA Interchangeable without loss of accuracy Factory adjustment with test protocol -25 ... +60 °C 0 ... 100 % -40 ... +120 °C ±2.5 % r.h. ±0,5 °C   Device in carton box, incl. Quickstart 1 Delivery time