DX 330 is a digital Indoor Air Quality (IAQ) probe for the PRO D01 / PRO D05 handheld meters. The probe measures:

  • Temperature
  • Relative humidity
  • Atmospheric pressure
  • CO2
  • VOC index.
The probe is supplied factory-calibrated, and it is ready to use.

The probe can be optionally supplied with a DAkkS/ACCREDIA calibration certificate.

The calibration data are stored in the probe, allowing for interchangeability without the need for recalibration.

Equipped with 4-pin M12 connector.

Output:
UART (TTL 3.3V)
Power supply:
3.3…6 Vdc
Power consumption:
< 6 mA typ.
Connection:
4-pole M12
Dimensions:
177 x 30 x 19 mm
Weight:
45 g approx.
Material:
ABS
Sensor:
Temperature/RH: CMOS
Pressure: Piezoresistive
CO2: Non-Dispersive Infrared (NDIR)
VOC: Metal-Oxide film
Measuring range:
Temperature: -20…+80 °C
RH: 0…100%
Pressure: 300…1250 hPa
CO2: 0…5000 ppm
VOC: 1…500 (dimensionless index)
Resolution:
Temperature: 0.1 °C
RH: 0.1 %
Pressure: 0.1 hPa
CO2: 1 ppm
VOC: 1
Accuracy:
Temperature: ± 0.1 °C (20…60 °C) / ± 0.2 °C (remaining range)
RH: ±2% (0…80%RH) / ±3% (80…100%RH) @ T=10…50 °C
Pressure: ± 0.5 hPa (300…1100 hPa / -20…65 °C)
CO2: ± (50 ppm + 3% of the measure) @ 25 °C / 1013 hPa
VOC: Relative quali
Operating conditions:
-20…+60 °C / 0…95 %RH non-condensing (*)
Response time:
Temperature/RH: 10 s (T63 with 1 m/s air flow)
CO2: < 120 s (T90 with 2 m/s air flow)
Temperature drift:
Pressure: ± 0.75 Pa/°C (0…55 °C / 700…1100 hPa)
CO2: 1 ppm/°C (-20…45 °C)
Accuracy CO2 :
± (50 ppm + 3% of the measure) @ 25 °C / 1013 hPa
Accuracy pressure :
± 0.5 hPa (300…1100 hPa / -20…65 °C)
Accuracy RH:
±2% (0…80%RH) / ±3% (80…100%RH) @ T=10…50 °C
Accuracy temperature:
± 0.1 °C (20…60 °C) / ± 0.2 °C (remaining range)
Accuracy VOC :
Relative qualitative measurement
Adjustment support:
Temperature (offset or 2 points), RH (2 points), CO2 (offset or 2 points), pressure (offset)
CO2 temperature drift:
1 ppm/°C (-20…45 °C)
Long-term drift CO2 :
5% of the measure/5 years
Long-term drift RH:
< 0.25 %RH/year
Long-term drift temperature:
< 0.03 °C/year
Measuring range CO2:
0…5000 ppm
Measuring range pressure:
300…1250 hPa
Measuring range RH:
0…100%
Measuring range temperature:
-20…+80 °C
Measuring range VOC:
1…500 (dimensionless index)
Pressure temperature drift:
± 0.75 Pa/°C (0…55 °C / 700…1100 hPa)
Resolution CO2 :
1 ppm
Resolution pressure:
0.1 hPa
Resolution RH:
0.1%
Resolution temperature:
0.1 °C
Resolution VOC:
1
Response time CO2:
< 120 s (T90 with 2 m/s air flow)
Response time Temperature/RH:
10 s (T63 with 1 m/s air flow)
Sensor CO2:
Non-Dispersive Infrared (NDIR)
Sensor pressure:
Piezoresistive
Sensor temperature/RH:
CMOS
Sensor VOC:
Metal-Oxide film
Long-term drift pressure:
± 0.33 hPa/year
 
 
Enquire for more information
please weait… Your data is being loaded...

Article no. Connection Brand Version Calibration Working temperature Measuring range air humidity Measuring range temperature Measuring range pressure Measuring range CO2 Measuring range VOC Cable Scope of delivery minimal quantity Quantity
PCE
486786 DX330-00-00 M12 connetor,for M12 connection cable or direct mounting SENSECA Interchangeable without loss of accuracy Factory adjustment with test protocol -25 ... +60 °C 0 ... 100 % -20 ... +80 °C 300 ... 1250 hPa 0 ... 5000 ppm 1 ... 500 digit Without cable Device in carton box, incl. Quickstart 1 Delivery time