Senseca Germany GmbH

DX 115 - Digital Pt100 immersion probe, large handle (e.g. for PRO D0x)

Producer

DX 115 is a high precision digital immersion wire wound Pt100 temperature probes for the PRO D01 / PRO D05 handheld meters.

The probe is supplied factory-calibrated, and it is ready to use. It can be optionally supplied with a DAkkS/ACCREDIA calibration certificate.

The calibration data are stored in the probe, allowing for interchangeability without the need for recalibration.

The user can adjust the probe in two points (offset and slope) or by setting R0 (sensor resistance @ 0 °C) and the Callendar-Van Dusen parameters.
Supplied with 1, 2 or 5 m cable with 4-pin M12 connector.

Output:
UART (TTL 3.3V)
Power supply:
3.3…6 Vdc
Power consumption:
<1 mA typ.
Connection:
4-pole M12
Dimensions:
Stem: Ø3 mm, L=130/230/300 mm (other lengths on request) Handle length 98 mm Cable: Ø4 mm, L=1, 2 or 5 m
Weight:
110 g approx. with 2 m cable
Sensor:
Pt100 (Wire Wound)
Measuring range:
Stem length 230 and 300 mm: -196…+500 °C insertion probe 150 mm: -196…+250 °C
Resolution:
0.01 °C
Accuracy:
±0.05 °C (t = 0 °C) ±0.1 °C (0 °C ≤ t ≤ 100 °C) ±0.2 °C (-50 °C ≤ t < 0 °C, 100 < t ≤ 250 °C) ±0.3 °C (t = remaining range)
Materials:
Stem: AISI 316 Handle: Polyamide (PA6-GF30) Cable: PVC (-20...+105 °C)
Protection degree:
IP67
Applications:
Immersion
Response time:
3 s
Handle Materials:
Polyamide (PA6-GF30), grommet Santoprene (up to +120 °C)
Response time (T63):
3 s
 
 
Enquire for more information
please weait… Your data is being loaded...

Article no. Connection Probe length Cable and length Measuring range Brand Accuracy Version Resolution Model Calibration Diameter probe tube Scope of delivery Measuring element minimal quantity Quantity
PCE
486229 DX115-00-300-L02 M12A connector, 4-pin, electronic in plug 300 mm 2 m PVC cable, -20 ... +105 °C -196 ... +500 °C SENSECA ±0.05 K @ 0°C, 0.1 K in the range of 0...100°C, resolution 0.01°C Interchangeable without loss of accuracy 0.01 °C Immersion probe, blunt Factory adjustment, exchangeable Ø3 mm, mineral insulated, bendable up to 50 mm before tip Device in black protective bag 460x85x55 mm with velcro closure, Quickstart Pt100, wire wound, high precision 1 Delivery time
487740 DX115-00-230-L02 M12A connector, 4-pin, electronic in plug 230 mm 2 m PVC cable, -20 ... +105 °C -196 ... +500 °C SENSECA ±0.05 K @ 0°C, 0.1 K in the range of 0...100°C, resolution 0.01°C Interchangeable without loss of accuracy 0.01 °C Immersion probe, blunt Factory adjustment, exchangeable Ø3 mm Device in black protective bag 460x85x55 mm with velcro closure, Quickstart Pt100, wire wound, high precision 1 Delivery time
487742 DX115-I3-150-L02 M12A connector, 4-pin, electronic in plug 150 mm 2 m PVC cable, -20 ... +105 °C -196 ... +500 °C SENSECA ±0.05 K @ 0°C, 0.1 K in the range of 0...100°C, resolution 0.01°C Interchangeable without loss of accuracy 0.01 °C Insertion probe Factory adjustment, exchangeable Ø3 mm Device in carton box, incl. Quickstart Pt100, wire wound, high precision 1 Delivery time