Article no. |
Order Code |
Protection class |
Connection |
Probe length |
Cable and length |
Measuring range |
Brand |
Accuracy |
Version |
Model |
Diameter probe tube |
Weight |
Probe handle |
Probe tube material |
Scope of delivery |
Reaction time T90 |
minimal quantity |
|
Product comparison |
609695
GF1TK-T3-GE
|
GF1TK-T3-GE
|
IP 67 (except plug) |
Mini flat pin plug |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +550 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Immersion probe Ø3 mm |
Ø3 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A |
Device in carton box |
Water 0.4 m/s <2 s, air 2 m/s approx. 40s |
11.00 |
green.png
|
|
609696
GF1TK-T3-LE-GE
|
GF1TK-T3-LE-GE
|
IP 67 (except plug) |
Loose ends with wire end ferrules |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +550 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Immersion probe Ø3 mm |
Ø3 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A |
Device in carton box |
Water 0.4 m/s <2 s, air 2 m/s approx. 40s |
11.00 |
green.png
|
|
609697
GF1TK-E3-GE
|
GF1TK-E3-GE
|
IP 67 (except plug) |
Mini flat pin plug |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +550 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Insertion probe Ø3 mm |
Ø3 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A |
Device in carton box |
Water 0.4 m/s <2 s, air 2 m/s approx. 40s |
11.00 |
green.png
|
|
609698
GF1TK-E3-LE-GE
|
GF1TK-E3-LE-GE
|
IP 67 (except plug) |
Loose ends with wire end ferrules |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +550 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Insertion probe Ø3 mm |
Ø3 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A |
Device in carton box |
Water 0.4 m/s <2 s, air 2 m/s approx. 40s |
11.00 |
green.png
|
|
609699
GF1TK-E1.5-GE
|
GF1TK-E1.5-GE
|
IP 67 (except plug) |
Mini flat pin plug |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +550 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Inserttion probe Ø1.5 mm |
Ø1.5 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A |
Device in carton box |
water 0.4 m/s < 1 s, air 2 m/s approx. 12 s |
11.00 |
green.png
|
|
609700
GF1TK-E1.5-LE-GE
|
GF1TK-E1.5-LE-GE
|
IP 67 (except plug) |
Loose ends with wire end ferrules |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +550 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Inserttion probe Ø1.5 mm |
Ø1.5 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A |
Device in carton box |
water 0.4 m/s < 1 s, air 2 m/s approx. 12 s |
11.00 |
green.png
|
|
611299
GF1TK-L3-GE
|
GF1TK-L3-GE
|
|
Mini flat pin plug |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +400 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Air / gas temperature probe |
Ø3 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A, punched |
Device in carton box |
Water 0.4 m/s <2 s, air 2 m/s approx. 40s |
11.00 |
green.png
|
|
611300
GF1TK-L3-LE-GE
|
GF1TK-L3-LE-GE
|
|
Loose ends with wire end ferrules |
100 mm |
1 m silicone cable, -50 ... +200 °C |
-65 ... +400 °C |
SENSECA |
Class 1: ±1.5°C or 0.40% across measuring range |
Type K, class 1, not potential-free |
Air / gas temperature probe |
Ø3 mm |
ca. 40 g |
Black silicon handle, -50 ... +250 °C |
V4A, punched |
Device in carton box |
Water 0.4 m/s <2 s, air 2 m/s approx. 40s |
11.00 |
green.png
|
|